============== == 1.42.03 === ============== -Fixed GX1920/GC1920C connection issue under National Instruments ============== == 1.42.02 === ============== -Fixed bug #229 ('bad user set'): Firmware Update 1.36 to 1.42 corrupts camera UserConfig files When users attempt to upload new firmware to an older camera that uses a non Factory ConfigFilePowerUp index. If the camera in question uses a ConfigFilePowerUp setting which is not Factory (default value), the firmware upload results in an assertion. -Fixed bug #227 ('glitch filter initialization'): SyncIn1GlitchFilter default 2000 not applied at startup. Fixed and correctly initialized and reported ============== == 1.42.01 === ============== -Fixed bug #225 (Binning Y > 1 tap imibalance) Using 1.42 and applying Binning Y greater then 1 can generate a tap imbalance. This bug was eliminated with this firmware update. Applies to all GE Kodak models. ============== ==== 1.42 ==== ============== -Added Camera Attributes, see "AVT Camera and Driver Attributes" doc: StreamFrameRateConstrain ChunkModeActive PayloadSize NonImagePayloadSize FrameStartTriggerOverlap SyncIn1GlitchFilter LensDrive (GX only) -EventControls added to all camera models. -GX column masking added. -If using ExposureMode = Auto, and GainMode = Auto simultaneously, priority is given to changes in exposure until ExposureAutoMax is reached, at which point priority is given to changes in gain. -RGB and YUV color modes added to GC2450C, GB2450C, GC1600CH. -(GX Only) Frames may receive the associated chunk mode data from the camera: [Bytes 1 – 4] acquisition count. [Bytes 5 – 8] user value. Not currently implemented. 0. [Bytes 9 – 12] exposure value. [Bytes 13 – 16] gain value. [Bytes 17 – 18] sync in levels. [Bytes 19 – 20] sync out levels. [Bytes 21 – 24] counter 1 value. Not currently implemented. 0. [Bytes 25 – 28] counter 2 value. Not currently implemented. 0. [Bytes 29 – 32] timer 1 value. Not currently implemented. 0. [Bytes 33 – 36] timer 2 value. Not currently implemented. 0. [Bytes 37 – 40] sequence count. Not currently implemented. 0. [Bytes 41 – 44] chunk ID. 1000. [Bytes 45 – 48] chunk length. To enable the receiving of this data, allocate your tPvFrame->AncillaryBuffer and enable the ChunkModeActive attribute. -Support for GX1920 and GX1920C added ============== ==== 1.38 ==== ============== -GX Only Release -Added Camera Attributes, see "AVT Camera and Driver Attributes" doc: EventControls ============== ==== 1.36 ==== ============== -3rd party support: XML register "RegMemoryFileCmdExecute" changed from WO to WR for Cognex compatibility ============== ==== 1.34 ==== ============== -DHCP bug fix: now works when multiple DHCP servers are active -AcquisitonStart is allowed while AcquisitionStop is in progress ============== ==== 1.28 ==== ============== -Added Camera Attributes, see "AVT Camera and Driver Attributes" doc: ConfigFile CameraName -first GC660, GC1290, GC1600H, GC2450, GC1280 release ============== ==== 1.26 ==== ============== -Added Camera Attributes, see "AVT Camera and Driver Attributes" doc: AcquisitionMode = SingleFrame, Multiframe, Recorder BandwidthCtrlMode StreamHoldCapacity Iris (GC only) -first GC750 release -first GC1380H, GC1350H release ============== ==== 1.22 ==== ============== -Added Camera Attributes, see "AVT Camera and Driver Attributes" doc: StreamHold SyncOut1Mode = GPO SyncOutGpoLevels -first GC series release ============== ==== 1.18 ==== ============== -Added DHCP/Auto-IP/Persistent-IP addressing modes. ============== ==== 1.10 ==== ============== -first release of GE640 ============== ==== 1.08 ==== ============== -Added Camera Attributes, see "AVT Camera and Driver Attributes" doc: ExposureMode = Auto, AutoOnce WhitebalMode = Auto, AutoOnce ============== ==== 1.06 ==== ============== -first release of color GE650C, GE1350C, GE1380C, GE1600C ============== ==== 1.04 ==== ============== -first release of GE1600 ============== ==== 1.02 ==== ============== -first release of GE1350 ============== ==== 1.00 ==== ============== -first release of GE1380 and GE650